production of electrical control and signaling equipment

S-11 line

Short description:

The S-11… type contact block is used to connect various circuits indirectly (through a pressure element). It can therefore be used as a limit switch to detect end positions, or as a safety switch to control the removal of covers.

S-11

S-11

contact block w/o mounting base, 9 mm rod
4691

S-11/2

contact block w/o mounting base, 19 mm rod
4692

S-11/3

contact block with mounting base, 10 mm rod
4720

S-11/5

contact block with mounting base, 9 mm rod
4723

Technical specifications:

Touch protection

For devices with touch protection class III.

Installation

The contact block is mounted on the mounting plate with an M4 screw according to the drawings.

Protection

IP 00, or the protection provided by the housing after installation

Operating mode

When the rod of the S-11.. contact block is pressed, the NC contact opens when the displacement reaches 1.5 mm, and the NO contact closes after reaching 5 mm. The total pressing distance of the pressure element is 6.5 mm. After the pressure force acting on the rod is removed, the pressure element returns to its normal state.

Connection terminals

The S11.. contact blocks are equipped with screw-type connection terminals.

Electrical load capacity and service life:

 

Rated current

10 A

Rated voltage

50 V ~

Service life

1E4 switching cycles

Flammability rating of plastic parts

For plastic parts in contact with live parts min. V2 (according to UL 94)

Creeping distances and air gaps

 min. 3 mm

Creeping resistance

 PTI 250

Application category

 D (IEC 335 – 1)

Connecting cable

max. 1.5 mm2

Relevant standard

MSZ EN 61058-1

 